Single Gas Detector – Dräger Pac® 6500

​The robust Dräger Pac® 6500 is your reliable companion under tough conditions.

The personal single-gas detection device measures CO, H2S, SO2 or O2 quickly and precisely. Quick sensor response times and a powerful battery also ensure safety.

Benefit

Single-gas detector

  • ​for personal air monitoring
  • detection of carbon monoxide, oxygen, hydrogen sulphide or sulphur dioxide
  • non-disposable

Strong performance for maximum safety

You can rely on the Dräger Pac 6500: the personal single-gas detection device warns against hazardous concentrations of carbon monoxide, hydrogen sulphide, sulphur dioxide or oxygen with precision and reliability.

Powerful sensors with a very low t-90 response time ensure quick reactions. The Pac 6500 is versatile thanks to its wide measurement range. For example, the CO sensor measures concentrations from 1 to 1,999 ppm, and the H2S sensor from 0.4 to 100 ppm.

Easy handling thanks to clear user guidance

The D-Light indicates whether functionality of the device has been tested and whether it is ready to use. The housing is also designed with your safety in mind: each sensor variant of the Dräger Pac 6500 features clearly visible colour coding, thereby minimising the chance of mistakes.

Robust design – even for the toughest conditions

The Pac 6500 can easily handle even extreme conditions. Depending on the sensor, temperatures from -40 °C to 55 °C and air pressures between 700 and 1,300 mbar can be tolerated.

A membrane filter protects the sensor from foreign matter such as dust and liquids. The shock-proof, chemical-resistant housing meets the requirements specified in the IP68 standard rating.

User-friendly display with all important information

The large display is word-free and clearly indicates the respective gas concentration. Other important information, such as the battery capacity, is also displayed. The bright backlighting ensures that all values are clearly legible in the dark.

360° alarm with various functions

If the Dräger Pac 6500 measures hazardous gas concentrations, it sets off an audible, visual and perceptible vibrating alarm. Two bright, flashing LEDs on the top and bottom of the device ensure that the alarm is easily visible from all sides. The acoustic signal reaches a volume of 90 dB. The display can show the peak concentration measured at any given moment. Earlier alarms registered can also be retrieved at a later time even if they have been acknowledged.

The Pac 6500 with oxygen sensor has two additional alarm thresholds in addition to the standard alarm threshold settings.

Data logger and event logger for analyses and reports

The Dräger Pac 6500 logs concentrations and events along with the date and time. The data can be loaded on a PC via an interface and processed further there.

Economical operational costs

All versions of the Pac 6500 are equipped with extremely durable DrägerSensors® and a powerful battery.

The Pac 6500 is protected against water, dust and other foreign bodies by a special membrane filter. When the filter becomes heavily soiled in use, you can quickly and easily replace it yourself. The device is then ready to use again right away.

Fast function test saves time and money

​Function tests and calibrations can be carried out especially efficient in the Dräger X-dock® calibration station. The automatic bump tests in the X-dock are a cost-efficient and convenient solution thanks to the short test duration and the extremely low consumption of test gas. The Pac 6500 is simply placed in the bump test station and automatically selects the correct setting.

Additional information

Key Facts

Application Personal Air Monitoring
Temperature Range -40°C – 55°C
Lifetime unlimited
Measurable gases CO, O2, H2S, SO2
Sensor type Single-Gas Detector

Technical Data

Battery Duration 2 years (24/7)
Weight 0.11 Kg
Degree of protection IP 68
Temperature Range -40°C – 55°C
Air humidity 10% to 90%
Air pressure (hPa) 700 – 1300

Features

Dual sensors No
D-Light Yes
Changable filter easy to change from outside / mechanical connection
Peak Yes
TLV / STEL Yes
Alarm Hold Yes

Approvals

ATEX I M1 Ex ia I Ma II 1G Ex ia IIC T4 Ga (Zone 0)
IECEx Ex ia I Ma Ex ia IIC T4 Ga
c CSA us Class I, Zone 0, AEx ia IIC T4 Ga, Class II, Division 1, Group E, F, G
CE Yes
GOST (EAC) Yes
Performance approval No
Shipping approval Yes